HZDZ-S3 Handheld Power Quality Analyzer

HZDZ-S3 Handheld Power Quality Analyzer

HZDZ-S3 Handheld Power Quality Analyzer 3 phase electricity meter field calibrator is specifically for waveform distortion occurs detection grid, high-precision test instrument harmonic content of voltage fluctuation and flicker and phase imbalance of power quality problems.

Product Details

HZDZ-S3 Handheld Power Quality Analyzer

Power Quality Analyzer is specifically for waveform distortion occurs detection grid, high-precision test instrument harmonic content of voltage fluctuation and flicker and phase imbalance of power quality problems.


HZDZ-S3 Handheld Power Quality Analyzer Input Characteristics

1. Voltage measuring range: 0~400V, auto.

2. Current measurement range

3. Clamp transformers (three): 5A/25A (standard)

                                100A/500A (optional)

                                400A/2000A (optional)

4. Phase angle measurement range: 0~359.99 °.

5. Frequency range: 45~55Hz.

6. Voltage number of channels: three channels (UA, UB, and UC).

7. Current number of channels: three channels (IA, IB, IC).

8.Maximum number of harmonic analysis: 63 times.

9. Intervals of 1 minute maximum storage period: 18 months

 

HZDZ-S3 Handheld Power Quality Analyzer Accuracy 

1. Electric parameter measurement part:  Voltage: ± 0.2%,  Frequency: ± 0.01Hz

 

                                                                  Current, power: ± 0.5%,  Phase: ± 0.2 °

 

2. Power quality parts: Fundamental voltage permissible error ≤ 0.5%F.S.

 

                                        Fundamental current allowable error: ¡ü 1%F.S.

 

3. Fundamental error of measurement of phase differencebetween voltage and current: ≤ 0.2 °

 

4. Harmonic voltage rate measurement error: ≤ 0.1%

 

5. Contain measurement error of harmonic current: ≤ 0.2%

 

6. Three-phase voltage unbalance error: ≤ 0.2%

 

7. Voltage deviation error: ≤ 0.2%

 

8. Voltage tolerance: ≤ 0.2%

 

  •  working temperature:-10 ℃ ~ + 40  ℃ ,  power supply: AC220V, frequency 45Hz-55Hz

  • power consumption: ≤ 3VA   , battery operating time: less than 10 hours ,  insulation:

 

1) input voltage and current on the chassis of theinsulation resistance: 100M Max.

 

2) power input terminals for shell under industrialfrequency 1.5KV (RMS), a 1-minute experiment.

 

9. Volume: 320mmx240mmx130mm

 

10. Weight: 2.0Kg  

 Power Quality Analyzer.jpgPower Quality Analyzer.jpg

              Side View                                            

Power Quality Analyzer.jpg 0.jpg 

Verified information

verified information.png


Do you want to get more information? Click "Send" now!

Power Quality Analyzer


Related Products
Email Us
Feedback
Huazheng Electric Manufacturing (Baoding) Co.,Ltd
Copyright © Huazheng Electric Manufacturing (Baoding) Co.,Ltd All rights reserved.